JAI CV-M7+(CL) Bayer Mosaic Changed

Question

I have a BayerToRGB conversion for the images produced by the Question/fr/fournisseurs/JAI">JAI CV-M7+ (CL) which is running fine. Now I bought a new camera and the conversion does not work properly any longer. Why?

Résponse

Résponse/fr/fournisseurs/JAI">JAI has changed the horizontal timing of the CV-M7+(CL) starting with the following serial numbers:
  • CV-M7+CL: E720451
  • CV-M7+: E710404
The timing change results in a shift of the pixel position by just one pixel. This has the consequence that also the Bayer patter has been shifted by one pixel which has to be taken into account when doing the Bayer conversion. Alternatively you can modify the offset setting in your frame grabber configuration to restore the old Bayer pattern on newer cameras.
­